Introduction

Up to now in the Technical guides the supposed operational range was from -10 ºC to 50 ºC. However, we wanted to check wider ranges so we performed some new extreme temperature tests on the final products obtaining amazing results and leading our technology to support now a new range from -30 ºC to +70 ºC.

Description of the tests

Only standard products were used, with regular components. All of them were manufactured in Libelium and checked by our Quality Control department.

These were the temperature levels to check:

  • Cold: -10, -15, -20, -25, -30 and -35 ºC
  • Heat: 40, 50, 60, 70 and 80 ºC

We used 2 temperature test chambers:

  • an industrial oven (capable of getting up to 400 ºC)
  • an industrial freezer (capable of getting down to -35 ºC)

One Plug & Sense! The unit deployed in the industrial freezer

Some of the unwanted effects monitored were:

  • There are no physical deterioration or damage
  • There are no reboots
  • Sleep cycles are done correctly
  • Sensor readings are done correctly
  • Transmission processes are completed correctly
  • Data is written on the SD card correctly

Test durations were from some hours to 7 days in some cases. Libelium also performed quick changes in temperature, rising up from the freezer to the oven and also dropping fast from the oven to the freezer. These fast changes are necessary to ensure good operation not only in stationary conditions but in transient cases.

The battery is a sensitive element so we run every test starting with 2 battery levels: full (100%) and low (20%).

Our engineers created software codes to check the main functionalities of each device. Basically, an IoT node performs these 3 major actions: sleep, read sensors, send information. To be more accurate, the total cycle is composed of these 12 processes: sleep, wake-up, general configuration, turn on the sensor board, read sensors, turn off the sensor board, create data frame, turn on the radio, configure the radio, send frame, check successful communication, turn off the radio, configure the sleep mode.

We created combinations of all different radios and all different models (sensor boards) to check the whole portfolio.

Nodes transmitted their diagnosis and status frames to real receivers (Meshlium devices, WiFi routers and Sigfox/LoRaWAN/cellular base stations).

Besides, we plotted images like the following ones to check the behaviour.

Temperature graph of a Plug & Sense! WiFi unit

Temperature graph of a Plug & Sense! 868 unit

Results of the tests

All the tests were successful for the [-30, +70] ºC temperature range: no unwanted effects or abnormal operation were observed within this range. These temporary extreme temperatures are supported, but the regular recommended usage is [-20, +60] ºC, mainly because of battery limitations.

Conclusions

Tests concluded successfully for the extreme range [-30, +70] ºC, being [-20, +60] ºC the recommended continued temperature range.

More info:

Watch how Libelium is powering the IoT Revolution

References: